Note:- To get list price(s)/quotation or Purchase, Please read Note at the end of the Page. |
| |
| Total Selected Products = 0 / Total Products = 323 |
| |
| Total Products Selected from this Category = 0 / Total Products in this Category = 57 |
| |
 | | Sr. No. | : | Z 01 | Code | : | GS51 | Size | : | VARIOUS SIZES | Select for Quotation / Purchase | : | | | Description | : | FLP/WP DOUBLE COMPRESSION, BRASS, NICKEL PLATED CABLE GLAND SUITABLE FOR GAS GROUP AREA II A & II B AS PER IS 2148 – 1981.CMRI CERTIFICATE NO CMRI/TC/H428 DT 30.04.96
CMRI-TC NO:CMRI/TC/H428 DT 30.04.96 |
|
 | | Sr. No. | : | Z 02 | Code | : | GS71 | Size | : | VARIOUS SIZES | Select for Quotation / Purchase | : | | | Description | : | FLP/WP PLUG, SUITABLE FOR GAS GROUP AREA II A & II B AS PER IS 2148 – 1981.CMRI CERTIFICATE NO CMRI/TC/H428 DT 30.04.96
CMRI-TC NO:CMRI/TC/H428 DT 30.04.96 |
|
 | | Sr. No. | : | Z 03 | Code | : | HA53 | Size | : | 120 MM DIA | Select for Quotation / Purchase | : | | | Description | : | DESIGN MANUFACTURE & SUPPLY OF FLP\WP JUNCTION BOX IN CAST ALUMINIUM LM-6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GAS GROUP I, IIA AND IIB AREA COMPLETE WITH MAXIMUM 12NOS.2.5SQMM ELMAX TYPE TERMINALS. MAXIMUM 6:3/4"ET CABLE ENTRY CAN BE PROVIDED AT THE BOTTOM. CMRI CERTIFICATE NO CMRI\TC\H286 Dt 14.3.96 Wt.2.5Kg.App.
CMRI-TC NO:CMRI/TC/H286 DT 14.03.96 |
|
 | | Sr. No. | : | Z 04 | Code | : | HA54 | Size | : | 160 MM DIA | Select for Quotation / Purchase | : | | | Description | : | CAST ALUMINIUM LM-6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GAS GROUP I, IIA AND IIB AREA COMPLETE WITH MAXIMUM 24NOS.2.5SQMM ELMAX TYPE TERMINALS. MAXIMUM 8:3/4"ET CABLE ENTRY CAN BE PROVIDED AT THE BOTTOM. 5:3/4"ET CABLE ENTRY CAN BE PROVIDED. CMRI CERTIFICATE NO CMRI\TC\H280 Dt 14.3.96 Wt.4.5Kg.App.
CMRI-TC NO:CMRI/TC/H280 DT 14.03.96 |
|
 | | Sr. No. | : | Z 05 | Code | : | HB52 | Size | : | 180 And 120 MM DIA | Select for Quotation / Purchase | : | | | Description | : | FLP/WP/EXPLOSION PROOF CAST ALUMINIUM (LM-6) POLE BOX SUITABLE FOR CABLES UP TO 16 SQMM. FUSE/MCB CAN BE MOUNTED INSIDE.
CMRI-TC NO:CMRI/TC/H346 DT 08.07.97 |
|
 | | Sr. No. | : | Z 06 | Code | : | HC52 | Size | : | 100 MM DIA | Select for Quotation / Purchase | : | | | Description | : | FLP/WP/EXPLOSION PROOF CAST ALUMINIUM (LM-6) ONLY STOP PBSTN WITH STAYPUT STOP & WITH NC CONTACT. DIRECT TERMINATION ON CONTACT ELEMENT. 2:3/4"ET CABLE ENTRIES WILL BE PROVIDED AT THE BOTTOM.
CMRI-TC NO:CMRI/TC/351 DT 09.07.97 |
|
 | | Sr. No. | : | Z 07 | Code | : | HD51 | Size | : | 100 MM DIA | Select for Quotation / Purchase | : | | | Description | : | FLP/WP/EXPLOSION PROOF CAST ALUMINIUM (LM-6) START/STOP PBSTN WITH STAYPUT STOP WIRED UPTO 3WAY ELMEX TYPE TERMINAL. SWITCHING CHAMBER & TERMINATION CHAMBER WILL BE OF CLEAR 100MM DIA EACH. NO CONTACT FOR START & NC CONTACT FOR STOP WILL BE PROVIDED. 2:3/4"ET CABLE ENTRIES WILL BE PROVIDED AT THE BOTTOM.
CMRI-TC NO:CMRI/TC/H282 DT 14.03.96 |
|
 | | Sr. No. | : | Z 08 | Code | : | HD51P | Size | : | 100MM DIA | Select for Quotation / Purchase | : | | | Description | : | SUPPLY OF FLP/WP 2 WAY P.B.PENDANTS IN CAST ALUMINIUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH N.BLACK SPRING RETURN ACTUATOR WITH NO CONTACT FOR HOIST N.YELLOW SPRING RETURN ACT. WITH NO CONTACT FOR LOWER. IT WILL BE WIRED UPTO 3-WAY ELMEX TYPE TERMINAL BLOCK. 1:3/4”CABLE ENTRY WILL BE AT THE TOP. ELEMENTS WILL BE HANSU/SIEMENS MAKE. BOTH CHAMBERS WILL HAVE 100MM.CLEAR DIA INSIDE
CMRI-TC NO:CMRI/TC/H282 DT 14.03.96 |
|
 | | Sr. No. | : | Z 09 | Code | : | HD52 | Size | : | 100 MM DIA | Select for Quotation / Purchase | : | | | Description | : | FLP/WP/EXPLOSION PROOF CAST ALUMINIUM (LM-6) ROTARY SWITCH ENCLOSURE WITH 1NO 16A 2POLE ON/OFF ROTARY SWITCH WIRED UPTO 4WAY ELMEX TYPE TERMINAL. ROTARY SWITCH TERIMINAL & TERMINATION CHAMBER (TOTAL 2 CHAMBERS) WILL BE OF 100MM DIA EACH. 2:3/4"ET CABLE ENTRIES WILL BE PROVIDED AT THE BOTTOM.
CMRI-TC NO:CMRI/TC/H282 DT 14.03.96 |
|
 | | Sr. No. | : | Z 10 | Code | : | HD53 | Size | : | 100 MM DIA | Select for Quotation / Purchase | : | | | Description | : | FLP/WP/EXPLOSION PROOF CAST ALUMINIUM (LM-6) ONLY STOP PBSTN WITH STAYPUT STOP WIRED UPTO 2WAY ELMEX TYPE TERMINAL. SWITCHING CHAMBER & TERMINATION CHAMBER WILL BE OF CLEAR 100MM DIA EACH. NC CONTACT FOR STOP WILL BE PROVIDED. 2:3/4"ET CABLE ENTRIES WILL BE PROVIDED AT THE BOTTOM.
CMRI-TC NO:CMRI/TC/H282 DT 14.03.96 |
|
 | | Sr. No. | : | Z 11 | Code | : | HD54 | Size | : | 100MM DIA | Select for Quotation / Purchase | : | | | Description | : | FLAME PROOF/WP P.B.STATION IN CAST ALUMINIUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA & IIB GAS GROUP AREA COMPLETE 1 NO. 65 MM DIA 90O SCALE AMMETER WIRED UPTO 2 NOS. 2.5 SQ. MM. TERMINAL 2:3/4” CABLE ENTRY WILL BE PROVIDED AT THE BOTTOM.
CMRI-TC NO:CMRI/TC/H282 DT 14.03.96 |
|
 | | Sr. No. | : | Z 12 | Code | : | HD55 | Size | : | 100 MM DIA | Select for Quotation / Purchase | : | | | Description | : | FLP/WP/EXPLOSION PROOF CAST ALUMINIUM (LM-6) START/STOP PBSTN WITH STAYPUT STOP. DIRECT TERMINATION ON CONTACT ELEMENT MOUNTED ON BASE. ONE CHAMEBER OF CLEAR 100MM DIA FOR TERMINATION & SWITCHING. NO CONTACT FOR START & NC CONTACT FOR STOP WILL BE PROVIDED. 2:3/4"ET CABLE ENTRIES WILL BE PROVIDED AT THE BOTTOM.
CMRI-TC NO:CMRI/TC/351 DT 09.07.97 |
|
 | | Sr. No. | : | Z 13 | Code | : | HD55P | Size | : | 80MM DIA | Select for Quotation / Purchase | : | | | Description | : | SUPPLY OF FLP/WP 2 WAY P.B.PENDANTS IN CAST ALUMINIUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH N.BLACK SPRING RETURN ACTUATOR WITH NO CONTACT FOR HOIST & N.YELLOW SPRING RETURN ACT. WITH NO CONTACT FOR LOWER. CABLE TERMINATION DIRECTLY ON CONTACT ELEMENT. 1:3/4”CABLE ENTRY WILL BE PROVIDED AT THE TOP. ELEMENTS WILL BE HANSU/SIEMENS MAKE.
CMRI-TC NO:CMRI/TC/351 DT 09.07.97 |
|
 | | Sr. No. | : | Z 14 | Code | : | HE51 | Size | : | 100 MM DIA | Select for Quotation / Purchase | : | | | Description | : | FLP/WP/EXPLOSION PROOF CAST ALUMINIUM (LM-6) START/STOP PBSTN WITH STAYPUT STOP, 1POLE 2WAY AUTO-MANUAL OR LOCAL REMOTE SELECTOR SWITCH WIRED UPTO 6WAY ELMEX TYPE TERMINAL. SWITCHING CHAMBER, SELECTOR SWITCH CHAMBER & TERMINATION CHAMBER (TOTAL 3 CHAMBERS) WILL BE OF CLEAR 100MM DIA EACH. NO CONTACT FOR START & NC CONTACT FOR STOP WILL BE PROVIDED.2:3/4"ET CABLE ENTRIES WILL BE PROVIDED AT THE BOTTOM.
CMRI-TC NO:CMRI/TC/H284 DT 14.03.96 |
|
 | | Sr. No. | : | Z 15 | Code | : | HE52 | Size | : | 100 MM DIA | Select for Quotation / Purchase | : | | | Description | : | FLP/WP/EXPLOSION PROOF CAST ALUMINIUM (LM-6) 3WAY PBSTN WITH STAYPUT STOP, 1POLE 2WAY AUTO-MANUAL OR LOCAL REMOTE SELECTOR SWITCH WIRED UPTO 8WAY ELMEX TYPE TERMINAL. SWITCHING CHAMBER, SELECTOR SWITCH CHAMBER & TERMINATION CHAMBER (TOTAL 3 CHAMBERS) WILL BE OF CLEAR 100MM DIA EACH. NO CONTACT FOR FORWARD/REVERSE & NC CONTACT FOR STOP WILL BE PROVIDED. 2:3/4"ET CABLE ENTRIES WILL BE PROVIDED AT THE BOTTOM.
CMRI-TC NO:CMRI/TC/H284 DT 14.03.96 |
|
 | | Sr. No. | : | Z 16 | Code | : | HE53 | Size | : | 100 MM DIA | Select for Quotation / Purchase | : | | | Description | : | FLP/WP/EXPLOSION PROOF CAST ALUMINIUM (LM-6) ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH 6A CAM TYPE 1POLE 2 WAY LOCAL/REMOTE OR A/M SWITCH, WITH 65MM DIA AMMETER SUITABLE FOR 1A CT, SUPPRESSED SCALE. IT WILL BE WIRED UP TO 4-WAY ELMEX TYPE TERMINAL BLOCK. 2:3/4" CABLE ENTRY WILL BE AT THE BOTTOM. SWITCH WILL BE KAYCEE & AMMETER WILL BE MECO/IMP MAKE. ALL THREE CHAMBERS WILL HAVE 100MM. CLEAR DIA INSIDE.
CMRI-TC NO:CMRI/TC/H284 DT 14.03.96 |
|
 | | Sr. No. | : | Z 17 | Code | : | HE54 | Size | : | 100 MM DIA | Select for Quotation / Purchase | : | | | Description | : | FLAME PROOF/WP ROTARY SWITCH IN CAST ALUMINIUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH 1NO 16A 2POLE ON OFF ROTARY SWITCH OF KAYCEE OR EQUIVALENT DIRECT TERMINATION ON SWITCH TERMINALS. 2:3/4”CABLE ENTRY WILL BE AT THE BOTTOM.
CMRI-TC NO:CMRI/TC/351 DT 09.07.97 |
|
 | | Sr. No. | : | Z 18 | Code | : | HE55 | Size | : | 180 And 120 MM DIA | Select for Quotation / Purchase | : | | | Description | : | FLP/WP/EXPLOSION PROOF CAST ALUMINIUM (LM-6) ROTARY SWITCH ENCLOSURE WITH 1NO 32A/40A/63A 3POLE ON/OFF ROTARY SWITCH MOUNTED IN 180MM DIA ENCLOSURE WIRED UPTO TERMINAL IN 120MM DIA ENCLOSURE. 2:3/4"ET CABLE ENTRIES WILL BE PROVIDED AT THE BOTTOM.
CMRI-TC NO:CMRI/TC/H346 DT 08.07.97 |
|
 | | Sr. No. | : | Z 19 | Code | : | HF56 | Size | : | 180 And 120 MM DIA | Select for Quotation / Purchase | : | | | Description | : | FLP/WP/EXPLOSION PROOF DOL STARTER IN CAST ALUMINIUM (LM-6) ENCLOSURE UPTO 10 HP WITH 9/16A CONTRACTOR THERMAL OVERLOAD RELAY & START/STOP PUSH BUTTONS ARE PROVIDED IN 180MM DIA CHAMBER. IT IS WIRED UPTO TERMINAL BLOCK IN 120MM DIA CHAMBER. 2:3/4"ET CABLE ENTRIES ARE PROVIDED AT THE BOTTOM
CMRI-TC NO:CMRI/TC/H346 DT 08.07.97 |
|
 | | Sr. No. | : | Z 20 | Code | : | HG51 | Size | : | 100 MM DIA | Select for Quotation / Purchase | : | | | Description | : | FLP/WP/EXPLOSION PROOF CAST ALUMINIUM (LM-6) START/STOP PBSTN WITH STAYPUT STOP, 65MM DIA, MISC AMMETER, WIRED UPTO 5WAY ELMEX TYPE TERMINAL. SWITCHING CHAMBER, AMMETER CHAMBER & TERMINATION CHAMBER (TOTAL 3 CHAMEBERS) WILL BE OF CLEAR 100MM DIA EACH. NO CONTACT FOR START & NC CONTACT FOR STOP WILL BE PROVIDED. 2:3/4"ET CABLE ENTRIES WILL BE PROVIDED AT THE BOTTOM.
CMRI-TC NO:CMRI/TC/H284 DT 14.03.96 |
|
 | | Sr. No. | : | Z 21 | Code | : | HK52 | Size | : | 100 MM DIA | Select for Quotation / Purchase | : | | | Description | : | FLP/WP/EXPLOSION PROOF CAST ALUMINIUM (LM-6) 3WAY PBSTN WITH STAYPUT STOP WIRED UPTO 5WAY ELMEX TYPE TERMINAL. SWITCHING CHAMBER & TERMINATION CHAMBER WILL BE OF CLEAR 100MM DIA EACH. NO CONTACT FOR FORWARD/REVERSE & NC CONTACT FOR STOP WILL BE PROVIDED. 2:3/4"ET CABLE ENTRIES WILL BE PROVIDED AT THE BOTTOM.
CMRI-TC NO:CMRI/TC/H282 DT 14.03.96 |
|
 | | Sr. No. | : | Z 22 | Code | : | HK52P | Size | : | 100MM DIA | Select for Quotation / Purchase | : | | | Description | : | FLP/WP 3 WAY P.B.PENDANTS IN CAST ALUMINIUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH N.BLACK SPRING RETURN ACTUATOR WITH NO CONTACT FOR HOIST & N.YELLOW SPRING RETURN ACT. WITH NO CONTACT FOR LOWER 1NO110V AC INDICATING LAMP FOR SUPPLY ON WILL BE PROVIDED. IT WILL BE WIRED UP TO 5 WAYS ELMAX TYPE TERMINAL BLOCK. NOS. SPARE TERMINALS WILL BE PROVIDED.1:3/4"CABLE ENTRY WILL BE AT THE TOP. ELEMENTS WILL BE HANSU/SIEMENS MAKE. BOTH CHAMBERS WILL HAVE 100MM.CLEAR DIA INSIDE.
CMRI-TC NO:CMRI/TC/H282 DT 14.03.96 |
|
 | | Sr. No. | : | Z 23 | Code | : | HL51 | Size | : | 100 MM DIA | Select for Quotation / Purchase | : | | | Description | : | FLP/WP/EXPLOSION PROOF CAST ALUMINIUM (LM-6) 3WAY PBSTN WITH STAYPUT STOP, 65MM DIA, MISC AMMETER, WIRED UPTO 5WAY ELMEX TYPE TERMINAL. SWITCHING CHAMBER, AMMETER CHAMBER & TERMINATION CHAMBER (TOTAL 3 CHAMEBERS) WILL BE OF CLEAR 100MM DIA EACH. NO CONTACT FOR FORWARD/REVERSE & NC CONTACT FOR STOP WILL BE PROVIDED. 2:3/4"ET CABLE ENTRIES WILL BE PROVIDED AT THE BOTTOM.
CMRI-TC NO:CMRI/TC/H284 DT 14.03.96 |
|
 | | Sr. No. | : | Z 24 | Code | : | HQ51 | Size | : | 100 MM DIA | Select for Quotation / Purchase | : | | | Description | : | FLP/WP/EXPLOSION PROOF CAST ALUMINIUM (LM-6) 4WAY PBSTN WITH STAYPUT STOP WIRED UPTO 6WAY ELMEX TYPE TERMINAL. TWO SWITCHING CHAMBERS & ONE TERMINATION CHAMBER (TOTAL 3 CHAMBERS) WILL BE OF CLEAR 100MM DIA EACH. NO CONTACT FOR START & NC CONTACT FOR STOP WILL BE PROVIDED. 2:3/4"ET CABLE ENTRIES WILL BE PROVIDED AT THE BOTTOM.
CMRI-TC NO:CMRI/TC/H284 DT 14.03.96 |
|
 | | Sr. No. | : | Z 25 | Code | : | HQ51P | Size | : | 100MM. DIA | Select for Quotation / Purchase | : | | | Description | : | SUPPLY OF FLP/WP 4 WAY P.B.PENDANTS IN CAST ALUMINIUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH N.GREEN SPRING RETURN ACTUATOR WITH NO CONTACT FOR START & N.RED SPRING RETURN ACTUATOR WITH NC CONTACT FOR STOP, N.BLACK SPRING RETURN ACTUATOR WITH NO CONTACT FOR HOIST & N.YELLOW SPRING RETURN ACT. WITH NO CONTACT FOR LOWER. IT WILL BE WIRED UP TO 6-WAY ELMAX TYPE TERMINAL BLOCK. NOS. SPARE TERMINALS WILL BE PROVIDED. 1:3/4"CABLE ENTRY WILL BE AT THE TOP. 1:3/4"CABLE ENTRY WILL BE BLOCKED. ELEMENTS WILL BE HANSU/SIEMENS MAKE. BOTH CHAMBERS WILL HAVE 100MM.CLEAR DIA INSIDE. TYPE AS PER YOUR SPECIFICATIONS.
CMRI-TC NO:CMRI/TC/H284 DT 14.03.96 |
|
 | | Sr. No. | : | Z 26 | Code | : | HR53 | Size | : | 265X208X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAMEPROOF 5WAY P.B.PENDANTS IN CAST ALUMINIUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH N.GREEN SPRING RETURN ACTUATOR WITH NO CONTACT FOR START & N.RED SPRING RETURN ACTUATOR WITH NC CONTACT FOR STOP, 1NO 110V AC INDICATING LAMP FOR SUPPLY ON, 1NOS N. BLACK ACT. WITH 1NO+1NC CONTACT FOR HOIST AND 1NO N.YELLOW ACT. FOR LOWER. IT WILL BE WIRED UP TO 8 WAY ELMAX TYPE TERMINAL BLOCK. 2:3/4"CABLE ENTRY WILL BE AT THE TOP ELEMENTS WILL BE HANSU/SIEMENS MAKE.
CMRI-TC NO:CMRI/TC/H607 DT 09.06.97 |
|
 | | Sr. No. | : | Z 27 | Code | : | HS51 | Size | : | 265X208X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAME PROOF/EXPLOSION PROOF CAST ALUMINIUM (LM-6) 6WAY P.B STATION/LCS/CONTROL STATION/LPBS/PENDANT WITH TWO CHAMBERS WIRED UPTO TERMINAL BLOCK. 2:3/4"ET CABLE ENTRES WILL BE PROVIDED AT TOP OR AT BOTTOM.
CMRI-TC NO:CMRI/TC/H607 DT 09.06.97 |
|
 | | Sr. No. | : | Z 28 | Code | : | HS51P | Size | : | 265X233X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAMEPROOF 6WAY P.B.PENDANTS IN CAST ALUMINIUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH N.GREEN SPRING RETURN ACTUATOR WITH NO CONTACT FOR START& N.RED SPRING RETURN ACTUATOR WITH NC CONTACT FOR STOP, 2NOS N. BLACK ACT. WITH 1NO+1NC CONTACT FOR HOIST, LEFT AND 2NO N.YELLOW ACT. FOR LOWER AND RIGHT. IT WILL BE WIRED UP TO 10 WAYS ELMAX TYPE TERMINAL BLOCK. 2:3/4"CABLE ENTRY WILL BE AT THE TOP. ELEMENTS WILL BE HANSU/SIEMENS MAKE.
CMRI-TC NO:CMRI/TC/H607 DT 09.06.97 |
|
 | | Sr. No. | : | Z 29 | Code | : | HS53 | Size | : | 265X208X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAME PROOF/EXPLOSION PROOF CAST ALUMINIUM (LM-6) 7WAY P.B STATION/LCS/CONTROL STATION/LPBS/PENDANT WITH TWO CHAMBERS WIRED UPTO TERMINAL BLOCK. 2:3/4"ET CABLE ENTRES WILL BE PROVIDED AT TOP OR AT BOTTOM.
CMRI-TC NO:CMRI/TC/H607 DT 09.06.97 |
|
 | | Sr. No. | : | Z 30 | Code | : | HS53P | Size | : | 265X233X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAMEPROOF 7WAY P.B.PENDANTS IN CAST ALUMINIUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH N.GREEN SPRING RETURN ACTUATOR WITH NO CONTACT FOR START & N.RED SPRING RETURN ACTUATOR WITH NC CONTACT FOR STOP, 1NO 110V AC INDICATING LAMP FOR SUPPLY ON, 2NOS NORMAL BLACK ACT. WITH 1NO+1NC CONTACT FOR HOIST, LEFT AND 2NO N.YELLOW ACT. FOR LOWER, RIGHT. IT WILL BE WIRED UP TO 12-WAY ELMAX TYPE TERMINAL BLOCK. 2:3/4"CABLE ENTRY WILL BE AT THE TOP. ELEMENTS WILL BE HANSU/SIEMENS MAKE.
CMRI-TC NO:CMRI/TC/H607 DT 09.06.97 |
|
 | | Sr. No. | : | Z 31 | Code | : | HU51 | Size | : | 265X208X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAME PROOF/EXPLOSION PROOF CAST ALUMINIUM (LM-6) 8WAY P.B STATION/LCS/CONTROL STATION/LPBS/PENDANT WITH TWO CHAMBERS WIRED UPTO TERMINAL BLOCK. 2:3/4"ET CABLE ENTRES WILL BE PROVIDED AT TOP OR AT BOTTOM.
CMRI-TC NO:CMRI/TC/H607 DT 09.06.97 |
|
 | | Sr. No. | : | Z 32 | Code | : | HU51P | Size | : | 265X233X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAMEPROOF 8WAY P.B.PENDANTS IN CAST ALUMINIUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH N.GREEN SPRING RETURN ACTUATOR WITH NO CONTACT FOR START & N.RED SPRING RETURN ACTUATOR WITH NC CONTACT FOR STOP, 3NOS NORMAL BLACK ACT. WITH 1NO+1NC CONTACT FOR HOIST, LEFT, FORWARD AND 3NO N.YELLOW ACT. FOR LOWER, RIGHT AND REVERSE. IT WILL BE WIRED UP TO 12 WAY ELMAX TYPE TERMINAL BLOCK. 2:3/4"CABLE ENTRY WILL BE AT THE TOP. ELEMENTS WILL BE HANSU/SIEMENS MAKE.
CMRI-TC NO:CMRI/TC/H607 DT 09.06.97 |
|
 | | Sr. No. | : | Z 33 | Code | : | HV51 | Size | : | 290X266X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAME PROOF/EXPLOSION PROOF CAST ALUMINIUM (LM-6) 12WAY P.B STATION/LCS/CONTROL STATION/LPBS/PENDANT WITH TWO CHAMBERS WIRED UPTO TERMINAL BLOCK. 2:3/4"ET CABLE ENTRES WILL BE PROVIDED AT TOP OR AT BOTTOM.
CMRI-TC NO:CMRI/TC/H410 DT 23.07.97 |
|
 | | Sr. No. | : | Z 34 | Code | : | HV51P | Size | : | 290X266X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAMEPROOF 12WAY PB.STATION IN CAST ALUMINUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH N.GREEN SPRING RETURN ACTUATOR WITH NO CONTACT FOR START & N.RED SPRING RETURN ACTUATOR WITH NC CONTACT FOR STOP, 5NOS NORMAL BLACK ACT. WITH 1NO+1NC CONTACT FOR HOIST, LEFT, FORWARD, M.HOIST, A. HOIST AND 5NO N.YELLOW ACT. FOR LOWER, RIGHT, REVERSE, M.LOWER AND A.HOIST. IT WILL BE WIRED UP TO 18-WAY ELMEX TYPE TERMINAL BLOCK. 2:3/4"CABLE ENTRY WILL BE AT THE TOP. ELEMENTS WILL BE HANSU/SIEMENS MAKE.
CMRI-TC NO:CMRI/TC/H410 DT 23.07.97 |
|
 | | Sr. No. | : | Z 35 | Code | : | HV52 | Size | : | 290X266X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAME PROOF/EXPLOSION PROOF CAST ALUMINIUM (LM-6) 9WAY P.B STATION/LCS/CONTROL STATION/LPBS/PENDANT WITH TWO CHAMBERS WIRED UPTO TERMINAL BLOCK. 2:3/4"ET CABLE ENTRES WILL BE PROVIDED AT TOP OR AT BOTTOM.
CMRI-TC NO:CMRI/TC/H410 DT 23.07.97 |
|
 | | Sr. No. | : | Z 36 | Code | : | HV52P | Size | : | 290X266X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAMEPROOF SUPPLY OF FLAMEPROOF 9WAY P.B.PENDANTS IN CAST ALUMINIUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH N.GREEN SPRING RETURN ACTUATOR WITH NO CONTACT FOR START & N.RED SPRING RETURN ACTUATOR WITH NC CONTACT FOR STOP, 1NO 110V AC INDICATING LAMP FOR SUPPLY ON, 3NOS NORMAL BLACK ACT. WITH 1NO+1NC CONTACT FOR HOIST, LEFT, FORWARD AND 3NOS N.YELLOW ACT. FOR LOWER, RIGHT, RES IN CAST ALUMINIUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH N.GREEN SPRING RETURN ACTUATOR WITH NO CONTACT FOR START & N.RED SPRING RETURN ACTUATOR WITH NC CONTACT FOR STOP, 1NO 110V AC INDICATING LAMP FOR SUPPLY ON, 3NOS NORMAL BLACK ACT. WITH 1NO+1NC CONTACT FOR HOIST, LEFT, FORWARD AND 3NOS N.YELLOW ACT. FOR LOWER, RIGHT, REVERSE. IT WILL BE WIRED UP TO 14-WAY ELMAX TYPE TERMINAL BLOCK. 2:3/4"CABLE ENTRY WILL BE AT THE TOP.
ELEMENTS WILL BE HANSU/SIEMENS MAKE.
CMRI-TC NO:CMRI/TC/H410 DT 23.07.97 |
|
 | | Sr. No. | : | Z 37 | Code | : | HV53 | Size | : | 290X266X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAME PROOF/EXPLOSION PROOF CAST ALUMINIUM (LM-6) 10WAY P.B STATION/LCS/CONTROL STATION/LPBS/PENDANT WITH TWO CHAMBERS WIRED UPTO TERMINAL BLOCK. 2:3/4"ET CABLE ENTRES WILL BE PROVIDED AT TOP OR AT BOTTOM.
CMRI-TC NO:CMRI/TC/H410 DT 23.07.97 |
|
 | | Sr. No. | : | Z 38 | Code | : | HV53P | Size | : | 290X266X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAMEPROOF 10WAY P.B.PENDANTS IN CAST ALUMINIUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH N.GREEN SPRING RETURN ACTUATOR WITH NO CONTACT FOR START & N.RED SPRING RETURN ACTUATOR WITH NC CONTACT FOR STOP, 4NOS NORMAL BLACK ACT. WITH 1NO+1NC CONTACT FOR HOIST, LEFT, FORWARD, M.HOIST AND 4NO N.YELLOW ACT. FOR LOWER, RIGHT, REVERSE AND M.LOWER. IT WILL BE WIRED UP TO 15 WAY ELMAX TYPE TERMINAL BLOCK. 2:3/4" CABLE ENTRY WILL BE AT THE TOP.
ELEMENTS WILL BE HANSU/SIEMENS MAKE.
CMRI-TC NO:CMRI/TC/H410 DT 23.07.97 |
|
 | | Sr. No. | : | Z 39 | Code | : | HV54 | Size | : | 290X266X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAME PROOF/EXPLOSION PROOF CAST ALUMINIUM (LM-6) 11WAY P.B STATION/LCS/CONTROL STATION/LPBS/PENDANT WITH TWO CHAMBERS WIRED UPTO TERMINAL BLOCK. 2:3/4"ET CABLE ENTRES WILL BE PROVIDED AT TOP OR AT BOTTOM.
CMRI-TC NO:CMRI/TC/H410 DT 23.07.97 |
|
 | | Sr. No. | : | Z 40 | Code | : | HV54P | Size | : | 290X266X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAMEPROOF 11WAY P.B.PENDANTS IN CAST ALUMINIUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH N.GREEN SPRING RETURN ACTUATOR WITH NO CONTACT FOR START & N.RED SPRING RETURN ACTUATOR WITH NC CONTACT FOR STOP, 1NO 110V AC INDICATING LAMP FOR SUPPLY ON, 4NOS NORMAL BLACK ACT. WITH 1NO+1NC CONTACT FOR HOIST, LEFT, FORWARD, M.HOIST & 4NOS N.YELLOW ACT. FOR LOWER, RIGHT, REVERSE AND M.LOWER. IT WILL BE WIRED UP TO 16 WAY ELMAX TYPE TERMINAL BLOCK. 2:3/4"CABLE ENTRY WILL BE AT THE TOP. ELEMENTS WILL BE HANSU/SIEMENS MAKE.
CMRI-TC NO:CMRI/TC/H410 DT 23.07.97 |
|
 | | Sr. No. | : | Z 41 | Code | : | HW51 | Size | : | 410X295X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAME PROOF/EXPLOSION PROOF CAST ALUMINIUM (LM-6) 13WAY P.B STATION/LCS/CONTROL STATION/LPBS/PENDANT WITH TWO CHAMBERS WIRED UPTO TERMINAL BLOCK. 2:3/4"ET CABLE ENTRES WILL BE PROVIDED AT TOP OR AT BOTTOM.
CMRI-TC NO:CMRI/TC/H408 DT 23.07.97 |
|
 | | Sr. No. | : | Z 42 | Code | : | HW51P | Size | : | 410X295X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAMEPROOF 13WAY P.B.PENDANTS IN CAST ALUMINIUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH N.GREEN SPRING RETURN ACTUATOR WITH NO CONTACT FOR START & N.RED SPRING RETURN ACTUATOR WITH NC CONTACT FOR STOP, 1NO 110V AC INDICATING LAMP FOR SUPPLY ON, 5NOS NORMAL BLACK ACT. WITH 1NO+1NC CONTACT FOR HOIST, LEFT,FORWARD,M.HOIST & A. HOIST 5 NOS N.YELLOW ACT. FOR LOWER, RIGHT, REVERSE AND M.LOWER AND A. LOWER. IT WILL BE WIRED UP TO 18-WAY ELMAX TYPE TERMINAL BLOCK. 2:1" CABLE ENTRY WILL BE AT THE TOP. ELEMENTS WILL BE HANSU/SIEMENS MAKE.
CMRI-TC NO:CMRI/TC/H408 DT 23.07.97 |
|
 | | Sr. No. | : | Z 43 | Code | : | HW52 | Size | : | 410X295X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAME PROOF/EXPLOSION PROOF CAST ALUMINIUM (LM-6) 14WAY P.B STATION/LCS/CONTROL STATION/LPBS/PENDANT WITH TWO CHAMBERS WIRED UPTO TERMINAL BLOCK. 2:3/4"ET CABLE ENTRES WILL BE PROVIDED AT TOP OR AT BOTTOM.
CMRI-TC NO:CMRI/TC/H408 DT 23.07.97 |
|
 | | Sr. No. | : | Z 44 | Code | : | HW52P | Size | : | 410X295X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAMEPROOF 14WAY P.B.PENDANTS IN CAST ALUMINIUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH N.GREEN SPRING RETURN ACTUATOR WITH NO CONTACT FOR START & N.RED SPRING RETURN ACTUATOR WITH NC CONTACT FOR STOP, 6NOS NORMAL BLACK ACT. WITH 1NO+1NC CONTACT FOR HOIST, LEFT, FORWARD, M.HOIST, A. HOIST, M.A.HOIST AND 6NO N.YELLOW ACT. FOR LOWER, RIGHT, REVERSE, M.LOWER , A. HOIST AND M.A.HOIST. IT WILL BE WIRED UP TO 20 WAYS ELMAX TYPE TERMINAL BLOCK. 2:1" CABLE ENTRY WILL BE AT THE TOP. ELEMENTS WILL BE HANSU/SIEMENS MAKE.
CMRI-TC NO:CMRI/TC/H408 DT 23.07.97 |
|
 | | Sr. No. | : | Z 45 | Code | : | HW53 | Size | : | 410X295X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAME PROOF/EXPLOSION PROOF CAST ALUMINIUM (LM-6) 15WAY P.B STATION/LCS/CONTROL STATION/LPBS/PENDANT WITH TWO CHAMBERS WIRED UPTO TERMINAL BLOCK. 2:3/4"ET CABLE ENTRES WILL BE PROVIDED AT TOP OR AT BOTTOM.
CMRI-TC NO:CMRI/TC/H408 DT 23.07.97 |
|
 | | Sr. No. | : | Z 46 | Code | : | HW53P | Size | : | 410X295X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAMEPROOF 15WAY P.B.PENDANTS IN CAST ALUMINIUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH N.GREEN SPRING RETURN ACTUATOR WITH NO CONTACT FOR START & N.RED SPRING RETURN ACTUATOR WITH NC CONTACT FOR STOP, 1NO 110V AC INDICATING LAMP FOR SUPPLY ON, 6NOS NORMAL BLACK ACT. WITH 1NO+1NC CONTACT FOR HOIST, LEFT, FORWARD,M.HOIST & A.HOIST,BELL 6 NOS N.YELLOW ACT. FOR LOWER, RIGHT, REVERSE AND M.LOWER AND A. LOWER AND BRIDGE LIGHT. IT WILL BE WIRED UP TO 20 WAYS ELMAX TYPE TERMINAL BLOCK. 2:1" CABLE ENTRY WILL BE AT THE TOP. ELEMENTS WILL BE HANSU/SIEMENS MAKE.
CMRI-TC NO:CMRI/TC/H408 DT 23.07.97 |
|
 | | Sr. No. | : | Z 47 | Code | : | HW54 | Size | : | 410X295X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAME PROOF/EXPLOSION PROOF CAST ALUMINIUM (LM-6) 16WAY P.B STATION/LCS/CONTROL STATION/LPBS/PENDANT WITH TWO CHAMBERS WIRED UPTO TERMINAL BLOCK. 2:3/4"ET CABLE ENTRES WILL BE PROVIDED AT TOP OR AT BOTTOM.
CMRI-TC NO:CMRI/TC/H408 DT 23.07.97 |
|
 | | Sr. No. | : | Z 48 | Code | : | HW54P | Size | : | 410X295X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAMEPROOF 16WAY P.B.PENDANTS IN CAST ALUMINIUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH N.GREEN SPRING RETURN ACTUATOR WITH NO CONTACT FOR START & N.RED SPRING RETURN ACTUATOR WITH NC CONTACT FOR STOP, 7NOS NORMAL BLACK ACT. WITH 1NO+1NC CONTACT FOR HOIST, LEFT, FORWARD, M.HOIST, A. HOIST, M.A .HOIST, BELL AND 7NO N.YELLOW ACT. FOR LOWER, RIGHT, REVERSE, M.LOWER,A.LOWER, M.A.LOWER,LIGHT IT WILL BE WIRED UP TO 24-WAY ELMEX TYPE TERMINAL BLOCK.2:1" CABLE ENTRY WILL BE AT THE TOP. ELEMENTS WILL BE HANSU/SIEMENS MAKE
CMRI-TC NO:CMRI/TC/H408 DT 23.07.97 |
|
 | | Sr. No. | : | Z 49 | Code | : | HX51 | Size | : | 410X295X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAME PROOF/EXPLOSION PROOF CAST ALUMINIUM (LM-6) 18WAY P.B STATION/LCS/CONTROL STATION/LPBS/PENDANT WITH TWO CHAMBERS WIRED UPTO TERMINAL BLOCK. 2:3/4"ET CABLE ENTRES WILL BE PROVIDED AT TOP OR AT BOTTOM.
CMRI-TC NO:CMRI/TC/H408 DT 23.07.97 |
|
 | | Sr. No. | : | Z 50 | Code | : | HX51P | Size | : | 410X295X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAMEPROOF 18WAY P.B.PENDANTS IN CAST ALUMINIUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH N.GREEN SPRING RETURN ACTUATOR WITH NO CONTACT FOR START & N.RED SPRING RETURN ACTUATOR WITH NC CONTACT FOR STOP, 8NOS NORMAL BLACK ACT. WITH 1NO+1NC CONTACT FOR HOIST, LEFT, FORWARD, M.HOIST, A.HOIST, M.A.HOIST, BELL AND 8NO N.YELLOW ACT. FOR LOWER, RIGHT, REVERSE, M.LOWER, A.HOIST, M.A.HOIST, LIGHT. IT WILL BE WIRED UP TO 28 WAY ELMEX TYPE TERMINAL BLOCK. 2:1" CABLE ENTRY WILL BE AT THE TOP. ELEMENTS WILL BE HANSU/SIEMENS MAKE.
CMRI-TC NO:CMRI/TC/H408 DT 23.07.97 |
|
 | | Sr. No. | : | Z 51 | Code | : | HX52 | Size | : | 410X295X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAME PROOF/EXPLOSION PROOF CAST ALUMINIUM (LM-6) 17WAY P.B STATION/LCS/CONTROL STATION/LPBS/PENDANT WITH TWO CHAMBERS WIRED UPTO TERMINAL BLOCK. 2:3/4"ET CABLE ENTRES WILL BE PROVIDED AT TOP OR AT BOTTOM.
CMRI-TC NO:CMRI/TC/H408 DT 23.07.97 |
|
 | | Sr. No. | : | Z 52 | Code | : | HX52P | Size | : | 410X295X75MM | Select for Quotation / Purchase | : | | | Description | : | FLAMEPROOF 17WAY P.B.PENDANTS IN CAST ALUMINIUM LM6 ENCLOSURE WITHOUT CANOPY SUITABLE FOR INSTALLATION IN GROUP IIA, IIB GAS AREA COMPLETE WITH N.GREEN SPRING RETURN ACTUATOR WITH NO CONTACT FOR START & N.RED SPRING RETURN ACTUATOR WITH NC CONTACT FOR STOP, 1NO 110V AC INDICATING LAMP FOR SUPPLY ON, 7NOS NORMAL BLACK ACT. WITH 1NO+1NC CONTACT FOR HOIST, LEFT, FORWARD, M.HOIST & A.HOIST, M.A.HOIST, BELL 7NOS N.YELLOW ACT. FOR LOWER, RIGHT REVERSE, M.LOWER, A. LOWER, M.A.LOWER AND BRIDGE LIGHT. IT WILL BE WIRED UP TO 25-WAY ELMEX TYPE TERMINAL BLOCK. 2:1" CABLE ENTRY WILL BE AT THE TOP. ELEMENTS WILL BE HANSU/SIEMENS MAKE.
CMRI-TC NO:CMRI/TC/H408 DT 23.07.97 |
|
 | | Sr. No. | : | Z 53 | Code | : | HY17 | Size | : | 285x108x108mm | Select for Quotation / Purchase | : | | | Description | : | CAST ALUMINIUM (LM-6 ALLOY) WEATHERPROOF HAND LAMP SUITABLE FOR 60W GLS LAMP OR 16W CFL LAMP WITHOUT BULB BUT WITH HEAT RESISTANT GLASS. 1:3/4” CABLE ENTRY WILL BE PROVIDED AT THE TOP AND WITH PVC CAP ON HANDLE.
CMRI-TC NO:CMRI/TC/H346 DT 08.07.97 |
|
 | | Sr. No. | : | Z 54 | Code | : | HY51 | Size | : | 80 MM DIA | Select for Quotation / Purchase | : | | | Description | : | FLP/WP/EXPLOSION PROOF DIRECT ENTRY LIMIT SWITCH IN CAST ALUMINIUM (LM-6) ENCLOSURE WITH ROLLER. 2:3/4"ET CABLE ENTRIES ARE PROVIED ON SIDES.
CMRI-TC NO:CMRI/TC/351 DT 09.07.97 |
|
 | | Sr. No. | : | Z 55 | Code | : | HY53 | Size | : | 220MMDX475MMH | Select for Quotation / Purchase | : | | | Description | : | FLP/WP/EXPLOSION PROOF LIGHT FITTING IN CAST ALUMINIUM (LM-6) ENCLOSURE WITH WEL GLASS LIGHT FITTING COMPLETE WITH WIRE GUARD, J HOOK & BOROSIL TOUGHENED GLASS SUITABLE FOR 80W/125W HPMV OR 160W MLL LAMP OR 200W INCANDESCENT LAMP. LOOP-IN & LOOP-OUT JB IS PROVIDED AT THE TOP.
CMRI-TC NO:CMRI/TC/605 DT 09.06.97 |
|
 | | Sr. No. | : | Z 56 | Code | : | HY55 | Size | : | 125MMDX310MMH | Select for Quotation / Purchase | : | | | Description | : | FLP/WP/EXPLOSION PROOF LIGHT FITTING WITH REACTOR VESSEL LAMP WITHOUT CONTROL GEAR. CONSTRUCTED FROM DIE CAST ALUMINIUM ALLOY LM-6, SUITABLE FOR INSTALLATION IN-GROUP IIA, IIB GAS AREA SUITABLE UPTO 60W OR 16W CFL 240V LAMP, BUT WITHOUT BULB, SWITCH WILL BE IN SEPARATE CHAMBER AT THE TOP FOR EASE OF MAINTENANCE. LOOP IN LOOP OUT CAN BE DONE. 1:3/4" CABLE ENTRY WILL BE PROVIDED.
CMRI-TC NO:CMRI/TC/605 DT 09.06.97 |
|
 | | Sr. No. | : | Z 57 | Code | : | HY57 | Size | : | 135MMDX370MMH | Select for Quotation / Purchase | : | | | Description | : | FLP/WP/EXPLOSION WITHOUT CONTROL GEAR. CONSTRUCTED FROM DIE CAST ALUMINIUM ALLOY LM-6, SUITABLE FOR INSTALLATION IN-GROUP IIA, IIB GAS AREA SUITABLE FOR 60W 240V LAMP, BUT WITHOUT BULB TERMINATION WILL BE IN SEPARATE CHAMBER AT TOP FOR EASE OF MAINTENANCE. PORCELEIN LAMP HOLDER, WIRE GUARD WILL BE PROVIDED. BOROSIL TOUGHENED GLASS IS PROVIDED 1:3/4" CABLE ENTRY WILL BE PROVIDED.
CMRI-TC NO:CMRI/TC/605 DT 09.06.97 |
|
|
|
| |
Note:- To get list price(s)/quotation or Purchase of Item(s), Please select the item(s) by just ticking the checkbox, after selecting required item(s) from a Product Category then Click Add to Selected Product List. After selecting whole required Item(s) from each Category, Click quotation for getting quotation of selected Item(s) & for Purchasing Click Customer. If you want to remove any item(s) from your selected Item(s) list, Deselect the Item(s) & Click Add to Selected Product List on every Product Category Page. |
| |
| Home | Products Category | Search | Quotation | Our Requirement | Job Vacancy | Feedback | Help |
| ©2009 Hansu Controls. All rights reserved. |
| |